5:1 pilot ratio, vented counterbalance valve - atmospherically referenced

Capacity: 120 gpm | Cavity: T-19A

  • Control: L 
  • Functional setting range: G
  • Seal material: N

*Image for illustration purposes only

Price available only for registered users

If you need help Contact Us!

Cavity T-19A
Series 4
Capacity 120 gpm
Pilot Ratio 5:1
Maximum Recommended Load Pressure at Maximum Setting 4615 psi
Maximum Setting 6000 psi
Factory Pressure Settings Established at 2 in³/min.
Maximum Valve Leakage at Reseat 5 drops/min.
Check Cracking Pressure 20 psi
Adjustment - No. of CCW Turns from Min. to Max. Setting 5
Operating Characteristic Standard
Reseat >85% of setting
Valve Hex Size 1 5/8 in.
Valve Installation Torque 350 - 375 lbf ft
Adjustment Screw Internal Hex Size 5/32 in.
Locknut Hex Size 9/16 in.
Seal kit - Cartridge Buna: 990119007
Seal kit - Cartridge Polyurethane: 990119002
Seal kit - Cartridge Viton: 990119006
Model Weight 3.58 lb.
999CAIGLGN00000