805311019 - 2-WAY - EVK 06/C5-00-00-00 - DANFOSS
Description: EVK 06/C5-00-00-00
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Direct Acting, Double Blocking 210 bar [3000 psi] • 40 l/min [10.6 US gpm]
This is a 2-way, 2-position, poppet type, direct acting, normally closed, bi-directional solenoid valve. In its de-energized condition, flow is blocked in both directions. Leakage in either direction is kept to a minimum due to the poppet design. When energized, flow can take place from port 2 to 1 and from 1 to 2. These valves come standard with a push pin manual override. These valves can be used to hold loads in position or interrupt a pressure line where flow is expected to pass in both directions in the de-energized condition. They do not suffer from momentary opening due to shock pressures.
805315119 - SOLENOID VALVE 2-WAY - SVP08-NCR-00-00-B-00 - DANFOSS
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow.
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 and from 1 to 2. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position or to interrupt a pressure line where flow normally passes in both directions. 
805315419 - SOLENOID VALVE 2-WAY - SVP10-NC-00-00-B-00 - DANFOSS
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated
230 bar [3300 psi] • 80 l/min [21 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 but is restricted in the opposite direction. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position and bypass excess oil to tank. 
805315519 - SOLENOID VALVE 2-WAY - SVP10-NCR-00-00-B-00 - DANFOSS
Description: SVP10-NCR-00-00-B-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY CLOSED
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow 230 bar [3300 psi] • 80 I/min [21 US gpm] 
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 and from 1 to 2. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position or to interrupt a pressure line where flow normally passes in both directions. 
805315619 - SOLENOID VALVE 2-WAY - SVP10-NO-00-00-B-00 - DANFOSS
Description: SVP10-NO-00-00-B-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY OPEN
Solenoid Valve, 2-way, Poppet Type, Normally Open, Pilot Operated 230 bar [3300 psi] • 80 I/min [21 US gpm] 
This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. In its de-energized condition, flow can take place from port 2 to 1 but is restricted in the other direction. When energized, flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override. These valves can be used to hold loads in position when energized or bypass excess oil to tank in a fail-safe way. 
805315819 - SOLENOID VALVE 2-WAY - SVP10-NOR-00-00-B-00 - DANFOSS
SVP10-NO
Solenoid Valve, 2-way, Poppet Type, Normally Open, Pilot Operated
230 bar [3300 psi] • 80 l/min [21 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. In its de-energized condition, flow can take place from port 2 to 1 but is restricted in the other direction. When energized, flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override. These valves can be used to hold loads in position when energized or bypass excess oil to tank in a fail-safe way.
02-175823 - SOLENOID VALVE 2-WAY - SV13-16-C-0-00 - DANFOSS
Description: SV13-16-C-0-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY CLOSED
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow 350 bar [5000 psi] • 132 l/min [35 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, low passes from port 1 to 2 but is blocked in the opposite direction. When energized, low passes from port 2 to 1 and from 1 to 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position or to interrupt a pressure line where low normally passes in both directions.
02-175819 - SOLENOID VALVE 2-WAY - SV13-20-C-0-00 - DANFOSS
Description: SV13-20-C-0-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY CLOSED
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow 350 bar [5000 psi] • 230 l/min [60 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, Low passes from port 1 to 2 but is 
blocked in the opposite direction. When energized, Low passes from port 2 to 1 and from 1 to 2. Due to the low leakage provided by the poppet design, 
these valves can be used to hold loads in position or to interrupt a pressure line where Low normally passes in both directions. 
805312919 - SOLENOID VALVE 2-WAY - SV08-22-02-00-00-B-00 - DANFOSS
Description: SV08-22-02-00-00-B-00
Function: 2 WAY-2 POS ON-OFF SPOOL VALVE
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow 230 bar [3300 psi] • 18 l/min [4.7 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition flow is blocked in both directions. When energized, flow can take place from port 2 to 1 and from 1 to 2. The value will be subject to normal spool leakage dependent on the pressure difference between the ports. These valves can be used to interrupt a pressure line where flow is expected to pass in both directions in the de-energized condition.
805343619 - SOLENOID VALVE 2-WAY - SVP08-CDB-00-00-B-00 - DANFOSS
SVP08-CDB
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Direct Acting, Double Blocking
230 bar [3300 psi] • 25 l/min [6.6 US gpm]
This is a 2-way, 2-position, poppet type, direct acting, normally closed, bi-directional solenoid valve. In its de-energized condition, flow is blocked in both directions. Leakage in either direction is kept to a minimum due to the poppet design. When energized, flow can take place from port 2 to 1 and from 1 to 2. These valves come standard with a push pin manual override. These valves can be used to hold loads in position or interrupt a pressure line where flow is expected to pass in both directions in the de-energized condition. They do not suffer from momentary opening due to shock pressures.
401AA00053A - 2-WAY - 3CP2-1.5S - DANFOSS
Description: 3CP2-1.5S
Function: Manual Push Valve, 2-Way, Normally Closed, Poppet Type with Check
Manual Push Valve, 2-Way, Normally Closed, PoppetType with Check 210 bar [3000 psi]• 15 I/min [4 US gpm]
This is a 2-way, normally closed, restricted, poppet type, push to open directional control valve. In the normal position, flow is blocked from 1 to 2. When the knob is manually pushed downward, port 1 is connected to port 2 through a pre-determined orifice. This valve is ideal for emergency lowering applications. It is not recommended to flow from port 2 to port 1. If this is needed, please consult the factory. 
565589 - 2-WAY - MPV1-10-K-0 - DANFOSS
Description: MPV1-10-K-0 
Function: Manual Pull Valve, 2-Way, Normally Closed, Poppet Type
Manual Pull Valve, 2-Way, Normally Closed, PoppetType 210 bar [3000 psi]• 45 I/min [12 US gpm] 
This is a 2-way, normally closed, poppet type, pull to open directional control valve. In the normal position, flow is blocked from 2 to 1, while free reverse flow takes place from port 1 to 2 after overcoming the spring bias. When the knob is manually pulled upward, port 1 is connected to port 2 allowing free flow in both directions. This valve is ideal for emergency lowering applications. 
132598 - CONTROL VALVE 2-WAY - CP710-1-B-0-C-080-S2 - DANFOSS
Description: CP710-1-B-0-C-080-S2
Function: Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, Atmospheric Vent
Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, Atmospheric Vent 210 bar [3000 psi]• 40 I/min [11 US gpm]
This is a 2-way, spool type, hydraulically piloted directional control valve with an atmospheric vent. It is available in normally open or normally closed configurations between ports 2 and 3, which shift when the pilot pressure at port 1 overcomes the opposing spring. Due to the atmospheric vent, the pilot pressure required to shift the valve is independent of the pressure in the line between port 2 and port 3. 
133028 - CONTROL VALVE 2-WAY - CP710-1-B-0-O-080-S2 - DANFOSS
Description: CP710-1-B-0-O-080-S2
Function: Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, Atmospheric Vent
Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, Atmospheric Vent 210 bar [3000 psi]• 40 I/min [11 US gpm]
This is a 2-way, spool type, hydraulically piloted directional control valve with an atmospheric vent. It is available in normally open or normally closed configurations between ports 2 and 3, which shift when the pilot pressure at port 1 overcomes the opposing spring. Due to the atmospheric vent, the pilot pressure required to shift the valve is independent of the pressure in the line between port 2 and port 3. 
137825 - CONTROL VALVE 2-WAY - CP712-11-U-0-C-080 - DANFOSS
Description: CP712-11-U-0-C-080
Function: Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, External Drain
Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, External Drain 450 bar [6500 psi]• 130 I/min [34 US gpm] 
This is a 2-way, spool type, hydraulically piloted directional control valve with external drain. It is available in normally open or normally closed configurations between ports 2 and 3 that shift when pilot pressure is applied to port 1. Due to the external drain, the pilot pressure required shift the valve is dependent on the pressure in port 4, which would normally be connected to tank. Due to the high pressure rating, this valve is ideal for use in transmission circuits to by-pass flow dividers. 
137549 - CONTROL VALVE 2-WAY - CP712-11-U-0-O-080 - DANFOSS
Description: CP712-11-U-0-O-080
Function: Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, External Drain
Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, External Drain 450 bar [6500 psi]• 130 I/min [34 US gpm] 
This is a 2-way, spool type, hydraulically piloted directional control valve with external drain. It is available in normally open or normally closed configurations between ports 2 and 3 that shift when pilot pressure is applied to port 1. Due to the external drain, the pilot pressure required shift the valve is dependent on the pressure in port 4, which would normally be connected to tank. Due to the high pressure rating, this valve is ideal for use in transmission circuits to by-pass flow dividers. 
11004144 - VALVE 2-WAY - CP710-8-B-0-C-080 - DANFOSS
Directional Control Valve, 2-Way, Spool Type, Hydraulic Pilot, External Drain
210 bar [3000 psi] • 40 l/min [11 US gpm]
This is a 2-way, spool type, hydraulically piloted directional control valve with external drain. It is available in normally open or normally closed configurations between ports 2 and 3 that shift when pilot pressure is applied to port 1. Due to the external drain, the pilot pressure required shift the valve is dependent on the pressure in port 4, which would normally be connected to tank. 
139659.000 - 2-WAY - CP240-5-B-0-E-C-XXX - DANFOSS
Description:  CP240-5-B-0-E-C-XXX
Function: Sequence Valve, Normally Open, Spool Type, Hydraulic Pilot, External Drain
Sequence Valve, Normally Open, Spool Type, Hydraulic Pilot, External Drain 210 bar [3000 psi]• 25 I/min [7 US gpm] 
This is a hydraulically pilot operated spool valve, normally open from port 2 to 3 with port 4 as a drain port connected to tank. When the pilot pressure on port 1 reaches the setting, the valve will begin to close port 2 to 3. This is ideal for sensing pressure in a remote area of a circuit to sequence another operation. 
565988 - 2-WAY - PSV10-10-S-0-24/ - DANFOSS
Description: PSV10-10-S-0-24
Function: Sequence Valve, Normally Closed, Spool Type, Hydraulic Pilot, External Drain
Sequence Valve, Normally Closed, Spool Type, Hydraulic Pilot, External Drain 210 bar [3000 psi]• 23I/min [6 US gpm] 
This is a hydraulically pilot operated spool valve, normally closed from port 2 to 3 with port 4 as a drain port connected to tank. When the pilot pressure on port 1 reaches the setting, the valve will begin to open port 2 to 3. This is ideal for sensing pressure in a remote area of a circuit to sequence another operation
800280329 - 2-WAY - VDP 06/NC-EN-1-00-XXX - DANFOSS
Description: VDP 06/NC-EN-1-00-XXX
Sequence Valve, Normally Closed, Spool Type, Hydraulic Pilot, Atmospheric Vent 315 bar [4600 psi]• 25 I/min [7 US gpm] 
This is a hydraulically pilot operated spool valve, normally closed from port 2 to 3 with an atmospheric vent. When the pilot pressure on port 1 reaches the setting, the valve will begin to open port 2 to 3. This is deal for sensing pressure in a remote area of a circuit to sequence another operation. 
QPABLAN - 2-WAY - QPABLAN - SUN HYDRAULICS
The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 1 of the valve and when the pressure at port 1 reaches the valve setting, port 2 connects to port 3 to vent a relief valve and unload the pump. This valve has a 20% ratio between unload setting and reset; when pressure at port 1 falls below 80% of the valve setting, port 2 is blocked from port 3 and the pump will come back online to recharge the accumulator. This valve requires a separate check valve between port 1 and the pump. Another version of the accumulator sense, pump unload valve, QCDB, includes a free-flow check valve for pump flows under 12 gpm (50 L/min)
805312819 - SOLENOID VALVE 2-WAY - SV08-22-01-00-00-B-00 - DANFOSS
Solenoid Valve, 2-way, Spool Type, Normally Open
230 bar [3300 psi] • 16 l/min [4.2 US gpm]
OPERATION AND DESCRIPTION
This is a 2-way, 2-position, spool type, direct acting, normally open solenoid valve. When de-energized, flow can take place from port 2 to 1 and from 1 to 2. In its energized condition, flow is blocked in both directions. The valve will be subject to normal spool leakage dependent on the pressure dfference between the ports. They come standard with a push pin manual override. These valves can be used to interrupt a pressure line where flow is expected to pass in both directions in the energized condition. 
805315319 - SOLENOID VALVE 2-WAY - SVP08-NOR-00-00-B-00 - DANFOSS
Solenoid Valve, 2-Way, Poppet Type, Normally Open, Pilot Operated with Reverse Free Flow230 bar [3300 psi] • 35 l/min [9 US gpm]
OPERATION AND DESCRIPTIONThis is a 2-way, 2-position, pilot-operated poppet-type solenoid valve, normally open in its de-energized state.When de-energized, flow is allowed in both directions— from port 2 to port 1 and from port 1 to port 2.When energized, flow is permitted only from port 1 to port 2, while flow in the reverse direction is blocked.
The poppet design minimizes leakage.Certain models offer an optional filter at port 2 and are supplied as standard with a push-pin manual override.
Typical applications include:

Load holding when the valve is energized


Interruption of a bidirectional pressure line


Fail-safe bypass of excess oil to the tank

11126197 - SOLENOID VALVE 2-WAY - SVP10-NC-M-00-00-B-00 - DANFOSS
Solenoid Valve, 2-Way, Poppet Type, Normally Closed, Pilot Operated230 bar [3300 psi] • 80 l/min [21 US gpm]
OPERATION AND DESCRIPTIONThis is a 2-way, 2-position, pilot-operated, poppet-type solenoid valve, normally closed in its de-energized state.When de-energized, flow is allowed from port 1 to port 2, while flow in the opposite direction is blocked.When energized, flow is allowed from port 2 to port 1, while reverse flow is restricted.