Flow Control

137701 - NEEDLE VALVE CP610-7-B-0E - DANFOSS
Needle Valve, Fully Adjustable, Fine Metering with Reverse Free Flow
350 bar [5000 psi] • 55 l/min [14 US gpm]
DESCRIPTION AND OPERATION
This is a needle valve with a reverse free flow check. It is a variable orifice used to create a pressure drop when flow passes from port 2 to 1, while allowing free flow when flow passes from 1 to 2. Clockwise rotation of the adjustment screw decreases the flow setting until it is completely closed. The setting can be locked by tightening lock nut or knob on the adjustment screw
83031019 - FLOW REGULATOR PSV10-NC-10-00-00-B-00 - DANFOSS
Description: PSV10-NC-10-00-00-B-00
Function: Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated
Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated 260 bar [3800 psi]• 40 I/min [10.6 US gpm] 
This is a 2-way, spool type, normally closed, non-compensated proportional flow control valve. In the de-energized condition, flow is blocked in both directions. Energizing the coil will proportionally open port 1 to 2. Used in conjunction with a compensator, the valve will act as the control orifice for a pressure compensated flow regulator. 
83019627 - FLOW REGULATOR PSV10-NC-25-00-00-B-00 - DANFOSS
Description: PSV10-NC-25-00-00-B-00
Function: Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated
Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated 260 bar [3800 psi]• 40 I/min [10.6 US gpm] 
This is a 2-way, spool type, normally closed, non-compensated proportional flow control valve. In the de-energized condition, flow is blocked in both directions. Energizing the coil will proportionally open port 1 to 2. Used in conjunction with a compensator, the valve will act as the control orifice for a pressure compensated flow regulator. 
850254119 - FLOW REGULATOR PSV10-NC-40-00-00-B-00 - DANFOSS
Description: PSV10-NC-40-00-00-B-00
Function: Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated
Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated 260 bar [3800 psi]• 40 I/min [10.6 US gpm] 
This is a 2-way, spool type, normally closed, non-compensated proportional flow control valve. In the de-energized condition, flow is blocked in both directions. Energizing the coil will proportionally open port 1 to 2. Used in conjunction with a compensator, the valve will act as the control orifice for a pressure compensated flow regulator. 
83037335 - FLOW REGULATOR PSV12-NC-60-00-00-B-00 - DANFOSS
Description: PSV12-NC-60-00-00-B-00
Function: Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated
Proportional Flow Control Valve, Spool Type, Normally Closed, Direct Acting, Non-Compensated 260 bar [3800 psi] • 80 I/min [21 US gpm] 
This is a 2-way, spool type, normally closed, non-compensated proportional flow control valve. In the de-energized condition, flow is blocked in both directions. Energizing the coil will proportionally open port 1 to 2. Used in conjunction with a compensator, the valve will act as the control orifice for a pressure compensated flow regulator. 
130160 - FLOW DIVIDER CP340-1-B-0-66 - DANFOSS
Flow Divider/Combiner, Fixed Ratio, Flow Synchronizing Option 
210 bar [3000 psi] • 45 l/min [12 US gpm]
This is a fixed ratio flow divider/combiner valve. In dividing mode, flow enters port 3 and passes across two fixed orifices in linked spools. If the pressure drop through one orifice is higher than the other, then the spools will move together to restrict the flow in the lower pressure outlet port. This maintains  equal pressure drops across the spools, thus maintaining the flow division in the outlet ports. In combining mode, flow will enter ports 2 and 4 pass  through the orifices, which causes the spools to move to restrict the higher-pressure inlet and maintain equal pressure drops and equal flow into the  valve.
02-171893 - FLOW REGULATOR NV1-8-S-0 - DANFOSS
Description: NV1-8-S-0
Needle Valve, Fully Adjustable 350 bar [S000 psi] • 11I/min [3 US gpm]
This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1. Clockwise rotation of the adjustment screw decreases the flow setting until it is completely closed. The setting can be locked by tightening lock nut or knob on the adjustment screw. 
02-172863 - FLOW REGULATOR NV1-8-K-0- DANFOSS
Description: NV1-8-K-0
Needle Valve, Fully Adjustable 350 bar [S000 psi] • 11I/min [3 US gpm]
This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1. Clockwise rotation of the adjustment screw decreases the flow setting until it is completely closed. The setting can be locked by tightening lock nut or knob on the adjustment screw. 
566553 - FLOW REGULATOR NV1-10-0-0 - DANFOSS
Description:  NV1-10-0-0 
Needle valve, Fully Adjustable, Fine Metering 210 bar [3000 psi]• 45 I/min [12 US gpm] 
This needle valve with fine metering is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1. Clockwise rotation of the adjustment screw decreases the flow setting until it is completely closed. 
11254421 - FLOW REGULATOR HFCV10-HRT-P-E-13.2-00 - DANFOSS
Description: HFCV10-HRT-P-E-13.2-00
Flow Control, Fully Adjustable, Pressure Compensated, Restrictive Type with Reverse Free Flow 350 bar [S000 psi]• 45 I/min [12 US gpm] 
This is a fully adjustable, restrictive type, pressure compensated flow control valve from port 1 to 2 with a reverse free flow check from port 2 to 1. The flow from port 2 will remain constant regardless of the pressure difference across the valve. Flow enters at port 1 and passes across an adjustable orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Flow from port 2 to 1 passes freely across an integral check valve.