Electrical on/off

805314019 - 3-WAY - SV10-23-01-00-00-B-00 - DANFOSS
Solenoid Valve, 3-way, 2-position, Spool Type
230 bar [3300 psi] • 35 l/min [9 US gpm]
This is a 3-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 1 is open to port 2 and port 3 is blocked. When energized, port 3 is open to port 1 and  port 2 is blocked. These valves can be used in normally open, normally closed or selector modes. They come standard with a push pin manual override. Always check the operating envelope to make sure the valve will work under the required application conditions.
805313019 - 3-WAY - SV08-23-01-00-00-B-00 - DANFOSS
Description: SV08-23-01-00-00-B-00
Function: 3 WAY-2 POS ON-OFF SPOOL VALVE 
Solenoid Valve, 3-way, 2 position, spool type 230 bar 3300 psi] • 18 l/min [4.8 US gpm]
This is a 3-way  2 position, spool type, direct acting solenoid valve. In the de-energized condition, port 1 is open and port 2 and port 3 is blocked. When energized, port 3 is open to port 1 and port 2 is blocked. These valvea can be used in normally open, normally closed or sector modes. THer come standard with a push pin manual overide. Always check the operating enevelope to make sure the valve will work under the required application conditions. 
805339919 - 3-WAY - SV08-23-04-00-00-B-00 - DANFOSS
Description: SV08-23-04-00-00-B-00
Function: 3 WAY-2 POS ON-OFF SPOOL VALVE
Solenoid Valve, 3-way, 2-position, Spool Type 230 bar [3300 psi]• 12I/min [3.2 US gpm] 
his is a 3-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 3 is open to port 2 and port 1 is blocked. When energized, port 2 is open to port 1 and port 3 is blocked. These valves can be used in normally open, normally closed or selector modes. Always check the operating envelope to make sure the valve will work under the required application conditions. 
805313219 - 3-WAY - SV08-23-03-00-00-B-00 - DANFOSS0-B-00 - DANFOSS
Description: SV08-23-03-00-00-B-00
Function: 3 WAY-2 POS ON-OFF SPOOL VALVE
Solenoid Valve, 3-way, 2-position, Spool Type230 bar [3300 psi]• 181/min [4.7 US gpm] 
This is a 3-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 1 is open to port 2 and port 3 is blocked. When energized, port 3 is open to port 2 and port 1 is blocked. These valves can be used in normally open, normally closed or selector modes. They come standard with a push pin manual override. Always check the operating envelope to make sure the valve will work under the required application conditions. 
800397929 - 3-WAY - EVH 06/D5-00-00-00 - DANFOSS
Description: EVH 06/D5-00-00-00
Function: 3 WAY-2 POS ON-OFF POPPET VALVE
Solenoid Valve, 3-way, 2-position, Poppet Type 230 bar [3300 psi] • 25 l/min [6.6 US gpm]
This is a 3-way, 2-position, poppet type, direct acting solenoid valve. When de-energized, the valve blocks flow from port 3 while allowing flow between port 1 and 2. When energized, the valve poppet blocks flow from port 1 while allowing flow between port 2 and 3. These valves come standard with a push pin manual override. This valve is ideal for low leakage requirements to hold a load in position.
11128605 - 3-WAY - EVH 06/D5-00-00-SPS-00 - DANFOSS
Solenoid Valve, 3-way, 2-position, Poppet Type
230 bar [3300 psi] • 25 l/min [6.6 US gpm]
OPERATION AND DESCRIPTION
This is a 3-way, 2-position, poppet type, direct acting solenoid valve. When de-energized, the valve blocks flow from port 3 while allowing flow between port 1 and 2. When energized, the valve poppet blocks fow from port 1 while allowing flow between port 2 and 3. These valves come standard with a push pin manual override. This valve is ideal for low leakage requirements to hold a load in position.
139811 - 3-WAY - CP521-21-B-0-00-00 - DANFOSS
Solenoid Valve, 3-Way, 2-Position, Spool Type240 bar [3500 psi] • 60 l/min [16 US gpm]
OPERATION AND DESCRIPTIONThis is a 3-way, 2-position, direct-acting solenoid valve with a spool-type design.In the de-energized state, port 1 is open to port 2, while port 3 is blocked.When energized, port 3 is open to port 1, and port 2 is blocked.
These valves can be configured for normally open, normally closed, or selector functions.They feature an open transition during shifting, which helps reduce pressure spikes when changing flow direction.

Always verify the valve’s operating parameters to ensure suitability for your specific application.