Logic Element

Subcategories

83052333 - LOGIC ELEMENT HLE10-OPO-2.75-B-00 - DANFOSS
Description: HLE10-OPO-2.75-B-00
Function: Logic Element, Normally Open, Spool Type, Pilot to Open
Logic Element, Normally Open, Spool Type, Pilot to Open 350 bar [S000 psi] • 60 I/min [16 US gpm] 
This is a 3-ported, normally open, pilot to open, spool type logic element. Flow is open from port 2 to port 1, until pressure in port 1 is sufficient to overcome the spring set pressure plus any pressure in port 3. The pressure in port 3 can be controlled remotely making the valve ideal for use as a normally open on/off element in a pressure reducing function. This valve is most commonly used as a pressure compensator in conjunction with a proportional directional valve. 
83025399 - LOGIC ELEMENT HLE10-OPO-5.5-B-00 - DANFOSS
Description: HLE10-OPO-5.5-B-00
Function:Logic Element, Normally Open, Spool Type, Pilot to Open
Logic Element, Normally Open, Spool Type, Pilot to Open 350 bar [S000 psi] • 60 I/min [16 US gpm] 
This is a 3-ported, normally open, pilot to open, spool type logic element. Flow is open from port 2 to port 1, until pressure in port 1 is sufficient to overcome the spring set pressure plus any pressure in port 3. The pressure in port 3 can be controlled remotely making the valve ideal for use as a normally open on/off element in a pressure reducing function. This valve is most commonly used as a pressure compensator in conjunction with a proportional directional valve. 
83024441 - LOGIC ELEMENT HLE10-OPO-7.5-B-00 - DANFOSS
Description: HLE10-OPO-7.5-B-00
Function:Logic Element, Normally Open, Spool Type, Pilot to Open
Logic Element, Normally Open, Spool Type, Pilot to Open 350 bar [S000 psi] • 60 I/min [16 US gpm] 
This is a 3-ported, normally open, pilot to open, spool type logic element. Flow is open from port 2 to port 1, until pressure in port 1 is sufficient to overcome the spring set pressure plus any pressure in port 3. The pressure in port 3 can be controlled remotely making the valve ideal for use as a normally open on/off element in a pressure reducing function. This valve is most commonly used as a pressure compensator in conjunction with a proportional directional valve. 
83023553 - LOGIC ELEMENT HLE10-OPO-10-B-00 - DANFOSS
Description: HLE10-OPO-10-B-00
Function:Logic Element, Normally Open, Spool Type, Pilot to Open
Logic Element, Normally Open, Spool Type, Pilot to Open 350 bar [S000 psi] • 60 I/min [16 US gpm] 
This is a 3-ported, normally open, pilot to open, spool type logic element. Flow is open from port 2 to port 1, until pressure in port 1 is sufficient to overcome the spring set pressure plus any pressure in port 3. The pressure in port 3 can be controlled remotely making the valve ideal for use as a normally open on/off element in a pressure reducing function. This valve is most commonly used as a pressure compensator in conjunction with a proportional directional valve. 
83025816055 - LOGIC ELEMENT HLE10-OPO-13-B-00 - DANFOSS
Description: HLE10-OPO-13-B-00
Function:Logic Element, Normally Open, Spool Type, Pilot to Open
Logic Element, Normally Open, Spool Type, Pilot to Open 350 bar [S000 psi] • 60 I/min [16 US gpm] 
This is a 3-ported, normally open, pilot to open, spool type logic element. Flow is open from port 2 to port 1, until pressure in port 1 is sufficient to overcome the spring set pressure plus any pressure in port 3. The pressure in port 3 can be controlled remotely making the valve ideal for use as a normally open on/off element in a pressure reducing function. This valve is most commonly used as a pressure compensator in conjunction with a proportional directional valve. 
83010873 - LOGIC ELEMENT CP701-1-B-0-170 - DANFOSS
Description: CP701-1-B-0-170
Function: Logic Element, Normally Closed, Spool Type, Pilot to Close
Logic Element, Normally Closed, Spool Type, Pilot to Close 3S0 bar [S000 psi]• 1 SO I/min [40 US gpm] 
This is a 3-ported, normally closed, pilot to close spool type logic element. By opening port 3 to tank, flow can pass from port 1 to port 2. Flow is blocked from port 1 to port 2 unless the pressure is high enough in port 1 to overcome the spring set pressure. Applying pressure to port 3 will increase the pressure required in port 1 to open the valve by a factor of 1 to 1. This valve is ideal for use as a pressure compensator, bypass valve, or a pilot to close valve in regenerative circuits. 
132736 - LOGIC ELEMENT CP300-4-B-0-0-080 - DANFOSS
Description: CP300-4-B-0-0-080
Pressure Compensator, Restrictive Type 210 bar [3000 psi]• 40 I/min [11 US gpm] 
This is a 3-ported spool valve, where port 3 is connected to port 2 and port 1 is the pilot port. The spring chamber is connected to port 3 through an orifice. When port 3 is connected to the outlet of a control orifice and port 1 is connected upstream of the orifice, the valve functions as a restrictive pressure compensator. When the pressure drop across the orifice is equal to the spring set pressure, the spool restricts flow from port 3 to port 2 and compensates for any change in pressure difference across the valve. 
134196 - LOGIC ELEMENT CP300-4-B-0-0-110 - DANFOSS
Description: CP300-4-B-0-0-110
Pressure Compensator, Restrictive Type 210 bar [3000 psi]• 40 I/min [11 US gpm] 
This is a 3-ported spool valve, where port 3 is connected to port 2 and port 1 is the pilot port. The spring chamber is connected to port 3 through an orifice. When port 3 is connected to the outlet of a control orifice and port 1 is connected upstream of the orifice, the valve functions as a restrictive pressure compensator. When the pressure drop across the orifice is equal to the spring set pressure, the spool restricts flow from port 3 to port 2 and compensates for any change in pressure difference across the valve. 
131976 - LOGIC ELEMENT CP300-4-B-0-0-150 - DANFOSS
Description: CP300-4-B-0-0-150
Pressure Compensator, Restrictive Type 210 bar [3000 psi]• 40 I/min [11 US gpm] 
This is a 3-ported spool valve, where port 3 is connected to port 2 and port 1 is the pilot port. The spring chamber is connected to port 3 through an orifice. When port 3 is connected to the outlet of a control orifice and port 1 is connected upstream of the orifice, the valve functions as a restrictive pressure compensator. When the pressure drop across the orifice is equal to the spring set pressure, the spool restricts flow from port 3 to port 2 and compensates for any change in pressure difference across the valve. 
132809 - LOGIC ELEMENT CP300-4-B-0-0-190 - DANFOSS
Description: CP300-4-B-0-0-190
Pressure Compensator, Restrictive Type 210 bar [3000 psi]• 40 I/min [11 US gpm] 
This is a 3-ported spool valve, where port 3 is connected to port 2 and port 1 is the pilot port. The spring chamber is connected to port 3 through an orifice. When port 3 is connected to the outlet of a control orifice and port 1 is connected upstream of the orifice, the valve functions as a restrictive pressure compensator. When the pressure drop across the orifice is equal to the spring set pressure, the spool restricts flow from port 3 to port 2 and compensates for any change in pressure difference across the valve. 
830100119 - VALVE VLP12/P2-B-00 - DANFOSS
Description: VLP12/P2-B-00
Logic Element Poppet, Double Blocking Closed, Vent to Open 315 bar [4600 psi] • 160 l/min [42 US gpm]
This is a 3-ported, normally closed, double blocking poppet type logic element, with port 1 connected to port 3 through an orifice. By opening port 3 to tank, flow can pass from port 1 to port 2 but not from port 2 to port 1. Closing port 3 will prevent the valve from opening from port 1 to port 2. The area ratio between port 1 and 3 is 1 to 1 and port 2 is balanced between the seat diameter and the seal poppet diameter. By controlling the flow or pressure out of port 3 the valve can be used as an on/ off valve or in a pressure control function.
FVCAXAN-10 - LOGIC ELEMENT - FVCAXAN-10 - SUN HYDRAULICS
CAPACITY: CAPACITY: 10 L/min
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely.