805314019 - SOLENOID VALVE 3-WAY - SV10-23-01-00-00-B-00 - DANFOSS
Solenoid Valve, 3-way, 2-position, Spool Type
230 bar [3300 psi] • 35 l/min [9 US gpm]
This is a 3-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 1 is open to port 2 and port 3 is blocked. When energized, port 3 is open to port 1 and  port 2 is blocked. These valves can be used in normally open, normally closed or selector modes. They come standard with a push pin manual override. Always check the operating envelope to make sure the valve will work under the required application conditions.
805314219 - SOLENOID VALVE 4-WAY - SV10-24-01-00-00-B-00 - DANFOSS
Solenoid Valve, 4-way, 2-position, Spool Type
230 bar [3300 psi] • 35 l/min [9 US gpm]
This is a 4-way, 2-position, spool type, direct acting solenoid valve. In the de-energized, condition port 3 is open to 2 and port 4 to 1. When energized port 3 is open to 4 and port 2 to 1. These valves are used to control the movement of cylinders or motors able to reverse the motion. Always check the  operating envelope to make sure the valve will work under the required application conditions. Port 1 is not intended for use as an inlet (Tank only).
805314919 - SOLENOID VALVE 2-WAY - SVP08-NC-00-00-B-00 - DANFOSS
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated 230 bar
[3300 psi] • 35 l/min [9 US gpm]
OPERATION AND DESCRIPTION
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 but is restricted in the opposite direction. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position and bypass excess oil to tank
805315119 - SOLENOID VALVE 2-WAY - SVP08-NCR-00-00-B-00 - DANFOSS
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow.
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 and from 1 to 2. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position or to interrupt a pressure line where flow normally passes in both directions. 
805315519 - SOLENOID VALVE 2-WAY - SVP10-NCR-00-00-B-00 - DANFOSS
Description: SVP10-NCR-00-00-B-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY CLOSED
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated with Reverse Free Flow 230 bar [3300 psi] • 80 I/min [21 US gpm] 
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 and from 1 to 2. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position or to interrupt a pressure line where flow normally passes in both directions. 
805315619 - SOLENOID VALVE 2-WAY - SVP10-NO-00-00-B-00 - DANFOSS
Description: SVP10-NO-00-00-B-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY OPEN
Solenoid Valve, 2-way, Poppet Type, Normally Open, Pilot Operated 230 bar [3300 psi] • 80 I/min [21 US gpm] 
This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. In its de-energized condition, flow can take place from port 2 to 1 but is restricted in the other direction. When energized, flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override. These valves can be used to hold loads in position when energized or bypass excess oil to tank in a fail-safe way. 
805315819 - SOLENOID VALVE 2-WAY - SVP10-NOR-00-00-B-00 - DANFOSS
SVP10-NO
Solenoid Valve, 2-way, Poppet Type, Normally Open, Pilot Operated
230 bar [3300 psi] • 80 l/min [21 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. In its de-energized condition, flow can take place from port 2 to 1 but is restricted in the other direction. When energized, flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override. These valves can be used to hold loads in position when energized or bypass excess oil to tank in a fail-safe way.
805339919 - SOLENOID VALVE 3-WAY - SV08-23-04-00-00-B-00 - DANFOSS
Description: SV08-23-04-00-00-B-00
Function: 3 WAY-2 POS ON-OFF SPOOL VALVE
Solenoid Valve, 3-way, 2-position, Spool Type 230 bar [3300 psi]• 12I/min [3.2 US gpm] 
his is a 3-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 3 is open to port 2 and port 1 is blocked. When energized, port 2 is open to port 1 and port 3 is blocked. These valves can be used in normally open, normally closed or selector modes. Always check the operating envelope to make sure the valve will work under the required application conditions. 
805347319 - SOLENOID VALVE 4-WAY - SV10-24-12-00-00-B-00 - DANFOSS
Description: SV10-24-12-00-00-B-00
Function: 4 WAY-2 POS ON-OFF SPOOL VALVE
Solenoid Valve, 4-way, 2-position, Spool Type 230 bar [3300 psi] • 25 l/min [6.6 US gpm]
This is a 4-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 3 is open to 1 while ports 2 and 4 are blocked. When energized, port 1 is open to 4 and port 2 open to 3. This valve allows the inlet oil to pass through the valve to tank or a separate system while holding the actuator in position. Always check the operating envelope to make sure the valve will work under the required application conditions. Port 1 is not intended as inlet (Tank only).