Electro Proportional

Solenoid valves are electrically-operated, on-off poppet or spool-type valves for load holding, blocking, or directional control applications.

11126197 - 2-WAY - SVP10-NC-M-00-00-B-00 - DANFOSS
Solenoid Valve, 2-Way, Poppet Type, Normally Closed, Pilot Operated230 bar [3300 psi] • 80 l/min [21 US gpm]
OPERATION AND DESCRIPTIONThis is a 2-way, 2-position, pilot-operated, poppet-type solenoid valve, normally closed in its de-energized state.When de-energized, flow is allowed from port 1 to port 2, while flow in the opposite direction is blocked.When energized, flow is allowed from port 2 to port 1, while reverse flow is restricted.

Some models are available with an optional filter at port 2.Thanks to the low leakage design of the poppet construction, these valves are ideal for applications requiring load holding or for safely diverting excess oil to tank.
805356019 - SOLENOID OPERATED CARTRIDGE SV10-23-01-24D-DN-B-00 - DANFOSS
Solenoid Valve, 3-way, 2-position, Spool Type
230 bar [3300 psi] • 35 l/min [9 US gpm]
This is a 3-way, 2-position, spool type, direct acting solenoid valve. In the de-energized condition, port 1 is open to port 2 and port 3 is blocked. When energized, port 3 is open to port 1 and  port 2 is blocked. These valves can be used in normally open, normally closed or selector modes. They come standard with a push pin manual override. Always check the operating envelope to make sure the valve will work under the required application conditions.
02-177582 - 2-WAY - SBV11-8-C-0-00 - DANFOSS
Description: SBV11-8-C-0-00
Function: 2 WAY-2 POS ON-OFF POPPET VALVE NORMALLY CLOSED
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated, Double Blocking 350 bar [S000 psi]• 45 I/min [12 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally closed, bi-directional solenoid valve. In its de-energized condition flow is blocked in both directions. Leakage in either direction is kept to a minimum due to the poppet design. When energized, flow can take place from port 2 to 1 and from 1 to 2. These valves can be used to hold loads in position or interrupt a pressure line where flow is expected to pass in both directions in the de-energized condition.