800299229 - CHECK, PILOT OPERATED - RPV 06-5-00 - DANFOSS
Pilot Operated Check Valve, Port 1 Pilot to open with Drain
315 bar [4600 psi]  30 l/min [8 US gpm]
DESCRIPTION AND OPERATION
This is a pilot operated check valve with a separate drain. Free flow takes place from port 3 to 4 and is blocked from port 4 to 3 until pilot pressure is applied to port 1. Port 2 is drained to tank to remove any effect of pressure in port 3 affecting the pilot pressure required to keep the valve open.
171185919 - COIL R16-12D-20W-DE - DANFOSS
Coils and Electronics
R16 - 20W Robust Coil
PERFORMANCE DATA:
Duty cycle: 100% at 133% of rated voltage and 70°C [158° F]
Magnet wire insulation: 200°C [392° F]
Ambient temperature range: -40 to +70 °C [-40 to 158 °F]
Input voltage range: 75% to 133% of rated voltage
171180619 - COIL R13-24D-16W-DE - DANFOSS
Using Danfoss Genuine Parts you can guarantee maximum reliability of your equipment, maximizing productivity and performance. By using non-original spare parts you will save on cost but a negative impact on the performance and strength of your equipment.
Function: R13 Deutsch
171140019 - COIL M13-24D-20W-DN - DANFOSS
Function: M13 DIN 43650
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
171111329 - COIL M19-24D-33W-DN - DANFOSS
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
171110719 - COIL M16-110A-26W-DN - DANFOSS
Description: M16-110A-26W-DN
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
11116123 - COIL R16-24D-20W-DEDB - DANFOSS
Coils and Electronics
R16 - 20W Robust Coil
PERFORMANCE DATA:
Duty cycle: 100% at 133% of rated voltage and 70°C [158° F]
Magnet wire insulation: 200°C [392° F]
Ambient temperature range: -40 to +70 °C [-40 to 158 °F]
Input voltage range: 75% to 133% of rated voltage
830100119 - LOGIC ELEMENT - VLP 12/P2-B-00 - DANFOSS
Description: VLP12/P2-B-00
Logic Element Poppet, Double Blocking Closed, Vent to Open 315 bar [4600 psi] • 160 l/min [42 US gpm]
This is a 3-ported, normally closed, double blocking poppet type logic element, with port 1 connected to port 3 through an orifice. By opening port 3 to tank, flow can pass from port 1 to port 2 but not from port 2 to port 1. Closing port 3 will prevent the valve from opening from port 1 to port 2. The area ratio between port 1 and 3 is 1 to 1 and port 2 is balanced between the seat diameter and the seal poppet diameter. By controlling the flow or pressure out of port 3 the valve can be used as an on/ off valve or in a pressure control function.
820174019 - FLOW REGULATOR - VRC 06-EN-3.00-00 - DANFOSS
Flow Control, Partially Adjustable, Pressure Compensated, Priority Type
315 bar [4600 psi] • 30 l/min [8 US gpm]
This is a partially adjustable, priority type, pressure compensated flow control valve, where the flow from port 3 will remain constant regardless of the pressure difference across the valve, while excess flow passes from port 1 to 2. Flow enters at port 1 and passes across a fixed orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Port 1 then opens to port 2 to allow excess flow to pass. The regulated flow will always take priority and remains constant if the working pressure is higher in either port 2 or port 3.
171184319 - COIL M16-110RA-22W-DN - DANFOSS
Description: M16-110RA-22W-DN
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
17115011 - COIL M16-12D-26W-AS - DANFOSS
Description: M16-12D-26W-AS
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier