800280329 - 2-WAY - VDP 06/NC-EN-1-00-XXX - DANFOSS
Description: VDP 06/NC-EN-1-00-XXX
Sequence Valve, Normally Closed, Spool Type, Hydraulic Pilot, Atmospheric Vent 315 bar [4600 psi]• 25 I/min [7 US gpm] 
This is a hydraulically pilot operated spool valve, normally closed from port 2 to 3 with an atmospheric vent. When the pilot pressure on port 1 reaches the setting, the valve will begin to open port 2 to 3. This is deal for sensing pressure in a remote area of a circuit to sequence another operation. 
800458339 - 3-WAY - VDP 06/4201-EN-1-00-XXX - DANFOSS
Description: VDP 06/4201-EN-1-00-XXX 
Sequence Valve, 3-Way, Spool Type, Hydraulic Pilot, Atmospheric Vent 315 bar [4600 psi]• 23I/min [6 US gpm] 
This is a hydraulically pilot operated spool valve where port 4 is closed and port 2 is open to port 3 in the neutral position. Pilot pressure is applied to port 1 and the spring chamber is referenced to atmosphere. When the pressure on port 1 reaches the setting, port 2 will begin to close and port 4 is opened to port 3. This valve can be used normally closed, normally open or as a diverter valve. 
11128605 - 3-WAY - EVH 06/D5-00-00-SPS-00 - DANFOSS
Solenoid Valve, 3-way, 2-position, Poppet Type
230 bar [3300 psi] • 25 l/min [6.6 US gpm]
OPERATION AND DESCRIPTION
This is a 3-way, 2-position, poppet type, direct acting solenoid valve. When de-energized, the valve blocks flow from port 3 while allowing flow between port 1 and 2. When energized, the valve poppet blocks fow from port 1 while allowing flow between port 2 and 3. These valves come standard with a push pin manual override. This valve is ideal for low leakage requirements to hold a load in position.
QPABLAN - 2-WAY - QPABLAN - SUN HYDRAULICS
The accumulator sense, pump unload pilot valve is used to sense pressure in an accumulator at port 1 of the valve and when the pressure at port 1 reaches the valve setting, port 2 connects to port 3 to vent a relief valve and unload the pump. This valve has a 20% ratio between unload setting and reset; when pressure at port 1 falls below 80% of the valve setting, port 2 is blocked from port 3 and the pump will come back online to recharge the accumulator. This valve requires a separate check valve between port 1 and the pump. Another version of the accumulator sense, pump unload valve, QCDB, includes a free-flow check valve for pump flows under 12 gpm (50 L/min)
FVCAXAN-10 - LOGIC ELEMENT - FVCAXAN-10 - SUN HYDRAULICS
CAPACITY: CAPACITY: 10 L/min
Ventable, bypass/restrictive, fixed-orifice, priority flow controls take an input flow at port 1 and use it to satisfy the priority flow at port 3. If the input flow exceeds the priority flow requirement, the excess is bypassed out port 2. The bypass flow may be used in a secondary circuit. A vent port (port 4) allows these valves to be controlled remotely. 
805312819 - 2-WAY - SV08-22-01-00-00-B-00 - DANFOSS
Solenoid Valve, 2-way, Spool Type, Normally Open
230 bar [3300 psi] • 16 l/min [4.2 US gpm]
OPERATION AND DESCRIPTION
This is a 2-way, 2-position, spool type, direct acting, normally open solenoid valve. When de-energized, flow can take place from port 2 to 1 and from 1 to 2. In its energized condition, flow is blocked in both directions. The valve will be subject to normal spool leakage dependent on the pressure dfference between the ports. They come standard with a push pin manual override. These valves can be used to interrupt a pressure line where flow is expected to pass in both directions in the energized condition. 
805315319 - 2-WAY - SVP08-NOR-00-00-B-00 - DANFOSS
Solenoid Valve, 2-Way, Poppet Type, Normally Open, Pilot Operated with Reverse Free Flow230 bar [3300 psi] • 35 l/min [9 US gpm]
OPERATION AND DESCRIPTIONThis is a 2-way, 2-position, pilot-operated poppet-type solenoid valve, normally open in its de-energized state.When de-energized, flow is allowed in both directions— from port 2 to port 1 and from port 1 to port 2.When energized, flow is permitted only from port 1 to port 2, while flow in the reverse direction is blocked.
The poppet design minimizes leakage.Certain models offer an optional filter at port 2 and are supplied as standard with a push-pin manual override.
Typical applications include:

Load holding when the valve is energized


Interruption of a bidirectional pressure line


Fail-safe bypass of excess oil to the tank

11126197 - 2-WAY - SVP10-NC-M-00-00-B-00 - DANFOSS
Solenoid Valve, 2-Way, Poppet Type, Normally Closed, Pilot Operated230 bar [3300 psi] • 80 l/min [21 US gpm]
OPERATION AND DESCRIPTIONThis is a 2-way, 2-position, pilot-operated, poppet-type solenoid valve, normally closed in its de-energized state.When de-energized, flow is allowed from port 1 to port 2, while flow in the opposite direction is blocked.When energized, flow is allowed from port 2 to port 1, while reverse flow is restricted.

Some models are available with an optional filter at port 2.Thanks to the low leakage design of the poppet construction, these valves are ideal for applications requiring load holding or for safely diverting excess oil to tank.
83023444 - 2-WAY - SVP10-NO-00-00-SPS-B-00 - DANFOSS
SVP10-NO
Solenoid Valve, 2-way, Poppet Type, Normally Open, Pilot Operated
230 bar [3300 psi] • 80 l/min [21 US gpm]
This is a 2-way, 2-position, poppet type, pilot operated, normally open solenoid valve. In its de-energized condition, flow can take place from port 2 to 1 but is restricted in the other direction. When energized, flow can take place from port 1 to 2 but is blocked in the other direction. Leakage is kept to a minimum due to the poppet design. Some models have the option of a filter around port 2, and these come standard with a push pin manual override. These valves can be used to hold loads in position when energized or bypass excess oil to tank in a fail-safe way.
139811 - 3-WAY - CP521-21-B-0-00-00 - DANFOSS
Solenoid Valve, 3-Way, 2-Position, Spool Type240 bar [3500 psi] • 60 l/min [16 US gpm]
OPERATION AND DESCRIPTIONThis is a 3-way, 2-position, direct-acting solenoid valve with a spool-type design.In the de-energized state, port 1 is open to port 2, while port 3 is blocked.When energized, port 3 is open to port 1, and port 2 is blocked.
These valves can be configured for normally open, normally closed, or selector functions.They feature an open transition during shifting, which helps reduce pressure spikes when changing flow direction.

Always verify the valve’s operating parameters to ensure suitability for your specific application.
130499 - LOGIC ELEMENT - CP701-1-B-0-030 - DANFOSS
Logic Element, Normally Closed, Spool Type, Pilot-to-Close350 bar [5000 psi] • 150 l/min [40 US gpm]
DESCRIPTION AND OPERATIONThis is a 3-port, normally closed, spool-type logic element with pilot-to-close functionality.When port 3 is open to tank, flow is allowed from port 1 to port 2.Flow from port 1 to port 2 is otherwise blocked unless the pressure at port 1 exceeds the spring setting.
Applying pilot pressure to port 3 increases the required opening pressure at port 1 at a 1:1 ratio.
This valve is ideal for use as a pressure compensator, bypass valve, or pilot-to-close element in regenerative hydraulic circuits.
83019507 - 2-WAY - SVP08-NC-00-00-M-B-00 - DANFOSS
Solenoid Valve, 2-way, Poppet Type, Normally Closed, Pilot Operated 230 bar
[3300 psi] • 35 l/min [9 US gpm]
OPERATION AND DESCRIPTION
This is a 2-way, 2-position, poppet type, pilot operated, normally closed solenoid valve. In its de-energized condition, flow passes from port 1 to 2 but is blocked in the opposite direction. When energized, flow passes from port 2 to 1 but is restricted in the opposite direction. Some models have the option of a filter at port 2. Due to the low leakage provided by the poppet design, these valves can be used to hold loads in position and bypass excess oil to tank
83021066 - 4-WAY - SV15-34-04-00-00-B-00 - DANFOSS
[3300 psi] • 50 l/min [13.2 US gpm]
This is a 4-way, 3-position, spool type, direct acting solenoid valve. In the center condition, ports 2 and 4 are closed while port 3 is connected to port 1. By energizing one coil, port 3 opens to 2 and port 4 to 1. When energizing the other coil, port 3 opens to 4 and port 2 to 1. This valve provides a directional control function with a neutral de energized state allowing the inlet flow to pass to tank or to another function while the work ports are blocked. It can be used in any hydraulic application where an actuator needs to be controlled in both directions. Always check the operating envelope to make sure the valve will work under the required application conditions. Port 1 is not intended for use as inlet (Tank only)