171150319 - COIL M16-24D-26W-AS - DANFOSS
Description: M16-24D-26W-AS 
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
• Magnet wire insulation: (200°C)
• Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
• Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
• Input voltage range: 85% to 115% of rated voltage
• Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
• AC coils require external rectier
• Weight: 0.24 kg [0.53 lb] 
11116122 - COIL R16-12D-20W-DEDB - DANFOSS
Coils and Electronics
R16 - 20W Robust Coil
PERFORMANCE DATA:
Duty cycle: 100% at 133% of rated voltage and 70°C [158° F]
Magnet wire insulation: 200°C [392° F]
Ambient temperature range: -40 to +70 °C [-40 to 158 °F]
Input voltage range: 75% to 133% of rated voltage
83020700 - REDUCING PPR09-POD-20-00-00-B-00 - DANFOSS
Description:PPR09-POD-20-00-00-B-00
Proportional Pressure Reducing, Relieving, Pilot Operated, Normally Open to Drain 50 bar [725 psi] • 25I/min [6.6 US gpm] 
This is a pilot operated, proportional pressure reducing/ relieving valve.In the de-energized condition, the inlet port 2 is blocked, while the reduced pressure in port 3 will be at the minimum setting and open to the tank port 4.By energizing the coil, the pressure in port 3 will increase proportionally to the current applied.Flow through port 2 to 3 is restricted to limit the pressure in port 3.In the case of over pressurization in port 3,the spool will open port 3 to port 4, which acts as a relief valve to limit the pressure in port 3.These valves are ideal for clutch control or as pilot valves for large directional control valves. 
83020704 - REDUCING PPR09-POD-25-00-00-B-00 - DANFOSS
Description:PPR09-POD-25-00-00-B-00
Proportional Pressure Reducing, Relieving, Pilot Operated, Normally Open to Drain 50 bar [725 psi] • 25I/min [6.6 US gpm] 
This is a pilot operated, proportional pressure reducing/ relieving valve.In the de-energized condition, the inlet port 2 is blocked, while the reduced pressure in port 3 will be at the minimum setting and open to the tank port 4.By energizing the coil, the pressure in port 3 will increase proportionally to the current applied.Flow through port 2 to 3 is restricted to limit the pressure in port 3.In the case of over pressurization in port 3,the spool will open port 3 to port 4, which acts as a relief valve to limit the pressure in port 3.These valves are ideal for clutch control or as pilot valves for large directional control valves.