171187819 - COIL D14E-12D-1.8A-DE - DANFOSS
Description: D14E-12D-1.8A-DE 
• Magnet wire insulation: (200°C)
• Maximum continuous current 1.8 A (at 12 V) 0.9 A (at 24 V)
• Ambient temperature: -40 to 50 °C [-40 to 122 °F]
• Environmental protection: IP69K: DE and FL connectors IP67: AJ and AS connectors IP65: all other connectors
• Used only on proportional valves with current control 
171187919 - COIL D14E-24D-0.9A-DE - DANFOSS
Description: D14E-24D-0.9A-DE
• Magnet wire insulation: (200°C)
• Maximum continuous current 1.8 A (at 12 V) 0.9 A (at 24 V)
• Ambient temperature: -40 to 50 °C [-40 to 122 °F]
• Environmental protection: IP69K: DE and FL connectors IP67: AJ and AS connectors IP65: all other connectors
• Used only on proportional valves with current control 
171142219 - COIL - M19-24D-33W-AJ - DANFOSS
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
171143019 - COIL - M19-24D-33W-DE - DANFOSS
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
171142919 - COIL - M19-12D-33W-DE - DANFOSS
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
171186819 - COIL - M19-12D-33W-DED - DANFOSS
Specification:
Duty cycle: 100% at 115% of rated voltage at 40°C [104°F]
Magnet wire insulation: (200°C)
Ambient temperature range: -20 to 40 °C [-4 to 104 °F]
Environmental protection rating: IP69K: DE IP67: AJ , AS, and M3 term IP65: FL and DN
Input voltage range: 85% to 115% of rated voltage
Temperature rise at 115% of rated voltage: 130°C [266°F] above ambient
AC coils require external rectier
800299229 - CHECK, PILOT OPERATED - RPV 06-5-00 - DANFOSS
Pilot Operated Check Valve, Port 1 Pilot to open with Drain
315 bar [4600 psi]  30 l/min [8 US gpm]
DESCRIPTION AND OPERATION
This is a pilot operated check valve with a separate drain. Free flow takes place from port 3 to 4 and is blocked from port 4 to 3 until pilot pressure is applied to port 1. Port 2 is drained to tank to remove any effect of pressure in port 3 affecting the pilot pressure required to keep the valve open.
820174019 - FLOW REGULATOR - VRC 06-EN-3.00-00 - DANFOSS
Flow Control, Partially Adjustable, Pressure Compensated, Priority Type
315 bar [4600 psi] • 30 l/min [8 US gpm]
This is a partially adjustable, priority type, pressure compensated flow control valve, where the flow from port 3 will remain constant regardless of the pressure difference across the valve, while excess flow passes from port 1 to 2. Flow enters at port 1 and passes across a fixed orifice in the spool, which creates a pressure drop. This causes the spool to move back against the spring, which then restricts the outlet flow. Port 1 then opens to port 2 to allow excess flow to pass. The regulated flow will always take priority and remains constant if the working pressure is higher in either port 2 or port 3.
83001762 - RELIEF VALVE WITH ANTICAVITATION - RV10-POP-3-E-XXX-B-00 - DANFOSS
Relief valve, Pilot Operated, Spool Type with Reverse Free Flow
250 bar [3600 psi] • 120 l/min [32 US gpm]
DESCRIPTION AND OPERATION
This is a pilot operated, poppet type relief valve that relieves from port 1 to port 2 with an integrated reverse flow check valve from port 2 to 1. Due to its unique poppet design, this valve offers faster response than a typical pilot operated valve. It can be used to limit pressure in a system or on a service line of a directional valve. It maintains accurate pressure control with constant or varying flows, while also allowing make up flow through in the reverse direction
810189519 - VALVE VEN 06-EN-3-00-XXX - DANFOSS
Relief Valve, Direct Acting, Poppet Type with Dampening
315 bar [4600 psi] • 40 l/min [11 US gpm]
DESCRIPTION AND OPERATION
This is a direct acting, poppet type relief valve that relieves from port 1 to 2. It features a highly damped poppet for smooth and stable response It can be used as a cost-effective main relief or to protect an actuator from over-pressurization.
850196119 - RELIEF VALVE PRV10-POC-215-C-00-00-E-B-00 - DANFOSS
Description: PRV10-POC-215-C-00-00-E-B-00  
Proportional Relief Valve, Spool Type, Pilot Operated, Normally Closed 250 bar [3600 psi] • 76 l/min [20 US gpm] 
This is a pilot operated, spool type, normally closed, proportional relief valve. In the de-energized condition, the pressure setting will be at a maximum. As current is applied to the coil, the pressure setting of the valve will decrease proportionally. This valve is ideal for use in cooling circuits to regulate the speed of the fan.
850258319 - FLOW REGULATOR - PFC12-PC-65-00-00-B-00 - DANFOSS
Proportional Flow Control Valve, Normally Closed, Priority Type, Pressure Compensated
260 bar [3800 psi] • 65 l/min [17 US gpm]
DESCRIPTION AND OPERATION
This is a 3-way, spool type, normally closed, priority type, pressure compensated proportional flow control valve. In the de-energized condition, flow is blocked from port 1 to the priority port 3 and all flow passes from port 1 to 2. Energizing the coil will proportionally move the spool, opening a variable orifice from port 1 to 3, while excess flow passes to port 2. An internal compensating spool ensures that the output flow at port 3 remains constant, regardless of changes in differential pressure between port 1 and 3 or pressure at the bypass port 2. Increasing the current to the coil will increase the priority outlet flow.
02-177194 - REDUCING - PRV12-10-I-0-15 - DANFOSS
Pressure Reducing Valve, Relieving, Pilot Operated
350 bar [5000 psi] • 45 l/min [12 US gpm]
DESCRIPTION AND OPERATION
This is a normally open, pilot operated pressure reducing valve. Port 2 is open to port 1 until the setting is reached, at which time the valve throttles the outlet low limiting the pressure. If the outlet pressure rises due to an external force, then the valve will open port 1 to port 3 acting as a relief valve. This valve is ideal for stable and precise control of a secondary pressure within a circuit
810209419 - RELIEF VALVE RV08-DR-3-E-XXX-B-00 - DANFOSS
Relief Valve, Direct Acting, Poppet Type with Dampening
250 bar [3600 psi] • 30 l/min [8 US gpm]
DESCRIPTION AND OPERATION
This is a direct acting, poppet type relief valve that relieves from port 1 to 2. It features a highly damped poppet for smooth and stable response. It can be used as a cost-effective main relief or to protect an actuator from over-pressurization.
850181119 - RELIEF VALVE XMP 06-70-00-00-00-00 - DANFOSS
Proportional Relief Valve, Spool Type, Pilot Operated, Normally Open
315 bar [4500 psi] • 50 l/min [13 US gpm]
DESCRIPTION AND OPERATION
This is a pilot operated, spool type, normally open, proportional relief valve. In the de-energized condition, the pressure setting will be at a minimum. As current is applied to the coil, the pressure setting of the valve will increase proportionally. This valve is ideal for system pressure control where flows may vary
850202619 - RELIEF VALVE XMP 06-150-00-00-00-00 - DANFOSS
Proportional Relief Valve, Spool Type, Pilot Operated, Normally Open
315 bar [4500 psi] • 50 l/min [13 US gpm]
DESCRIPTION AND OPERATION
This is a pilot operated, spool type, normally open, proportional relief valve. In the de-energized condition, the pressure setting will be at a minimum. As current is applied to the coil, the pressure setting of the valve will increase proportionally. This valve is ideal for system pressure control where flows may vary